Corporate Home Page 1-Commercial/Industrial 2-Poultry-Animal 3-Construction/Temporary 4-Garage/Residential
Radiant Heat Features Radiant Heat Benefits  TUBE HEATERS - Tube Heater Overview - CB Series - LTU Series - LTS Series - ETS/U Series - PTS/U Series - RSTP Series  CERAMIC HEATERS - Ceramic Heater Overview - DK Series - RSCA Series
 ENGINEERING & DESIGN SERVICES - Compuheat Heat Loss Analysis - Short Form Specifications - Infrared Heating Engineering Manual  TECHNICAL SUPPORT - Sequence of Operations - Installation & Operating Instructions - Submittals - Troubleshooting Guide
Typical Applications Case Studies
Questions about Products Questions about Space-Ray All Other Questions
What's New! Space-Ray E-Newsletters E-Newsletters Sign Up
Overview History Parent Company Info.
Request Quote Email Us General Info. Maps Directions
Welcome to Space-Ray - Infrared Gas Heaters


Infrared Radiant Heating for Commercial / Industrial Applications

commercial / industrial > products > tube heater - CB series

 

Specifications

Features

  • Four different input sizes from 20,000 to 50,000 Btu/hr
  • Natural or propane gas
  • U-tube design for uniform energy distribution
  • Compact size for easy installation from 6' to 20' above floor.

     

  • Radiant Emitter Tube System:

  • 3" O.D. calorized aluminized steel emitter tube for long life and high radiant efficiency
  • 5-year limited warranty on the emitter tube
  • Smooth cast iron "U" bend

     

  • Vacuum System

  • Products of combustion are pulled through the combustion chamber for increased radiant efficiency
    and greater safety
  • No draft hoods; totally enclosed combustion chamber

     

  • Burner System

  • One-piece cast iron burner
  • 10-year limited warranty on burner
  • Direct outside air for combustion
  • 4" O.D. combustion air intake and vent
  • Direct spark ignition system with step opening gas valve and 100% Gas Shut-Off Safety Control (pre-purge)
  • Monitoring lights for visual diagnosis of maintenance needs

     

  • Reflector System

  • Highly efficient aluminum reflectors
  • Reflector ends are enclosed for maximum radiant heat output and minimum convection loss
  • Suitable for horizontal or angle mount up to 45 degrees

     

  • Other

  • Lower mounting height kit required on heater installations between 6 and 8 feet
  • Optional deflector kit for reduced clearances to combustible materials
  • Optional decorative grille kit for drop ceiling applications

  •  

    Cold Blocker Infrared Tube HeaterCold Blocker with Emitter Guard

     

    CB Series
    Product Brochures:

     

    Installation & Operating
    Instructions:

    Other Major Types of
    Space-Ray Tube Heaters:

    LTU Series

    LTS Series

    ETS / ETU Series

    PTS / PTU Series

    RSTP Series

     

    Dimensions
      
    View Dimensions for Cold Blocker Infrared Radiant Gas Tube Heater
     

    MODEL

    INPUT
    BTU/HR

    MINIMUM MOUNTING HEIGHT TOTAL TUBE LENGTH OVERALL DIMENSION

    CB20

    20,000

    8'

    15'

    9' 3"

    CB30

    30,000

    8'

    15'

    9' 3"

    CB40

    40,000

    8'

    15'

    9' 3"

    CB50

    50,000

    8' 15' 9' 3"
     
     

    Supply Requirements

    < back to top >

     

    Clearance Information
     < back to top >

    NOTE: The clearances specified above must be maintained to combustibles and other materials that may be damaged by temperatures 90ºF above ambient temperature. Clearances to combustibles are posted on the reflector near the control end of the heater. In locations used for storage of combustible materials where they may be stacked below the heater, NFPA 54 requires that the installer must post signs that will "specify the maximum permissible stacking height to maintain the required clearances from the heater to combustibles".

     
    < back to top >
     


    Accessories

    Deflector Kit

    Deflector Kit for CB Infrared Heater


    Lower Mounting Kit
    Lower Mounting Kit for CB Infrared Radiant Gas HeatThe Lower Mounting Kit (Part #43515000) is required when the CB series of infrared tube heaters is installed at mounting heights between 6 ft. and 8 ft. above a finished floor. The Lower Mounting Kit consists of both the Emitter Guard Kit and the Draft Inducer Guard Kit as described below. 

    1. Emitter Guard Kit
    The Emitter Guard Kit (Part #43485000) includes an aluminum decorative grille with side emitter guard holder panels.  This item and the Draft Inducer Guard Kit make up the Lower Mounting Kit, which must be used in installations with mounting heights between 6 ft. and 8 ft.  This item could be used separately in installations above 8 ft., however, for decorative purposes if desired.


    details on Emitter Guard Kit (PDF)


    2. Draft Inducer Guard Kit
    The Draft Inducer Guard Kit (Part #43486000) is an aluminum shield mounted around the draft inducer (brackets and screws included). 

    This item and the Emitter Guard Kit make up the Lower Mounting Kit, which must be used in installations with mounting heights between 6 ft. and 8 ft.

    details on Draft Inducer Kit (PDF)

     
     
     
    < back to top >
    < back to top >

    To request a quote or if you need additional information, please call Space-Ray toll free at 800-438-4936 or send us an email.

    Besides this Commercial / Industrial Infrared gas heating product line, other Space-Ray divisions include: Poultry, Construction & Garage

    | home | about us | products: industrial / poultry / construction / garage | news2use | contact info. | email us | site map |

    © 2006 Copyright — Space-Ray, Division of Gas Fired Products, Inc. — Charlotte, North Carolina   USA
    International Manufacturer of Infrared Radiant Gas Heaters

    return HOME email us
       
     
     
    return HOME email us