MODEL |
INPUT
BTU/HR |
MINIMUM
MOUNTING HEIGHT |
TOTAL
TUBE LENGTH |
OVERALL
DIMENSION "L" |
|
ETS40-15
|
40,000
|
10'
|
15'
|
17'
9"
|
|
ETS50-15
|
50,000
|
11'
|
15'
|
17'
9"
|
|
ETS40-20
|
40,000
|
10'
|
20'
|
22'
9"
|
|
ETS50-20
|
50,000
|
11'
|
20'
|
22'
9"
|
|
ETS60-20
|
60,000
|
12'
|
20'
|
22'
9"
|
|
ETS75-20
|
75,000
|
13'
|
20'
|
22'
9"
|
|
ETS50-30
|
50,000
|
11'
|
30'
|
32'
9"
|
|
ETS60-30
|
60,000
|
12'
|
30'
|
32'
9"
|
|
ETS75-30
|
75,000
|
13'
|
30'
|
32'
9"
|
|
ETS80-30
|
80,000
|
13'
|
30'
|
32'
9"
|
|
ETS90-30
|
90,000
|
13'
|
30'
|
32'
9"
|
|
ETS100-30
|
100,000
|
14'
|
30'
|
32'
9"
|
|
ETS110-30
|
110,000
|
14'
|
30'
|
32'
9"
|
|
ETS120-30
|
120,000
|
14'
|
30'
|
32'
9"
|
|
ETS125-30
|
125,000
|
14'
|
30'
|
32'
9"
|
|
ETS130-30
|
130,000
|
15'
|
30'
|
32'
9"
|
|
ETS80-40
|
80,000
|
13'
|
40'
|
42'
9"
|
|
ETS90-40
|
90,000
|
13'
|
40'
|
42'
9"
|
|
ETS100-40
|
100,000
|
14'
|
40'
|
42'
9"
|
|
ETS110-40
|
110,000
|
14'
|
40'
|
42'
9"
|
|
ETS120-40
|
120,000
|
14'
|
40'
|
42'
9"
|
|
ETS125-40
|
125,000
|
14'
|
40'
|
42'
9"
|
|
ETS130-40
|
130,000
|
15'
|
40'
|
42'
9"
|
|
ETS140-40
|
140,000
|
15'
|
40'
|
42'
9"
|
|
ETS150-40
|
150,000
|
15'
|
40'
|
42'
9"
|
|
ETS160-40
|
160,000
|
16'
|
40'
|
42'
9"
|
|
ETS175-40
|
175,000
|
16'
|
40'
|
42'
9"
|
|
ETS125-40
|
125,000
|
14'
|
45'
|
47'
9"
|
|
ETS125-50
|
125,000
|
14'
|
50'
|
52'
9"
|
|
ETS130-50
|
130,000
|
15'
|
50'
|
52'
9"
|
|
ETS140-50
|
140,000
|
15'
|
50'
|
52'
9"
|
|
ETS150-50
|
150,000
|
15'
|
50'
|
52'
9"
|
|
ETS160-50
|
160,000
|
16'
|
50'
|
52'
9"
|
|
ETS175-50
|
175,000
|
16'
|
50'
|
52'
9"
|
|
ETS180-50
|
180,000
|
18'
|
50'
|
52'
9"
|
|
ETS200-50
|
200,000
|
18'
|
50'
|
52'
9"
|
|
ETS225-50
|
225,000
|
20'
|
50'
|
52'
9"
|
|
ETS250-50*
|
250,000
|
20'
|
50'
|
52'
9"
|
|
ETS180-60
|
180,000
|
18'
|
60'
|
62'
9"
|
|
ETS200-60
|
200,000
|
18'
|
60'
|
62'
9"
|
|
ETS225-60
|
225,000
|
20'
|
60'
|
62'
9"
|
|
ETS250-60
|
250,000
|
20'
|
60'
|
62'
9"
|
|
ETS180-70
|
180,000
|
18'
|
70'
|
72'
9"
|
|
ETS200-70
|
200,000
|
18'
|
70'
|
72'
9"
|
|
ETS225-70
|
225,000
|
20'
|
70'
|
72'
9"
|
|
ETS250-70
|
250,000
|
20'
|
70'
|
72'
9"
|
|
ETS180-80
|
180,000
|
18'
|
80'
|
82'
9"
|
|
ETS200-80
|
200,000
|
18'
|
80'
|
82'
9"
|
|
ETS225-80
|
225,000
|
20'
|
80'
|
82'
9"
|
|
ETS250-80
|
250,000
|
20'
|
80'
|
82'
9"
|
MODEL |
INPUT
BTU/HR |
MINIMUM
MOUNTING HEIGHT |
TOTAL
TUBE LENGTH |
OVERALL
DIMENSION "L" |
| ETU40-20 |
40,000 |
10' |
20' |
12'
9" |
| ETU50-20 |
50,000 |
11' |
20' |
12'
9" |
| ETU60-20 |
60,000 |
12' |
20' |
12'
9" |
| ETU75-20 |
75,000 |
13' |
20' |
12'
9" |
| ETU50-30 |
50,000 |
11' |
30' |
17'
9" |
| ETU60-30 |
60,000 |
12' |
30' |
17'
9" |
| ETU75-30 |
75,000 |
13' |
30' |
17'
9" |
| ETU80-30 |
80,000 |
13' |
30' |
17'
9" |
| ETU90-30 |
90,000 |
13' |
30' |
17'
9" |
| ETU100-30 |
100,000 |
14' |
30' |
17'
9" |
| ETU110-30 |
110,000 |
14' |
30' |
17'
9" |
| ETU120-30 |
120,000 |
14' |
30' |
17'
9" |
| ETU125-30 |
125,000 |
14' |
30' |
17'
9" |
| ETU130-30 |
130,000 |
15' |
30' |
17'
9" |
| ETU80-40 |
80,000 |
13' |
40' |
22'
9" |
| ETU90-40 |
90,000 |
13' |
40' |
22'
9" |
| ETU100-40 |
100,000 |
14' |
40' |
22'
9" |
| ETU110-40 |
110,000 |
14' |
40' |
22'
9" |
| ETU120-40 |
120,000 |
14' |
40' |
22'
9" |
| ETU125-40 |
125,000 |
14' |
40' |
22'
9" |
| ETU130-40 |
130,000 |
15' |
40' |
22'
9" |
| ETU140-40 |
140,000 |
15' |
40' |
22'
9" |
| ETU150-40 |
150,000 |
15' |
40' |
22'
9" |
| ETU160-40 |
160,000 |
16' |
40' |
22'
9" |
| ETU175-40 |
175,000 |
16' |
40' |
22'
9" |
| ETU125-50 |
125,000 |
14' |
50' |
27'
9" |
| ETU130-50 |
130,000 |
15' |
50' |
27'
9" |
| ETU140-50 |
140,000 |
15' |
50' |
27'
9" |
| ETU150-50 |
150,000 |
15' |
50' |
27'
9" |
| ETU160-50 |
160,000 |
16' |
50' |
27'
9" |
| ETU175-50 |
175,000 |
16' |
50' |
27'
9" |
| ETU180-50 |
180,000 |
18' |
50' |
27'
9" |
| ETU200-50 |
200,000 |
18' |
50' |
27'
9" |
| ETU225-50 |
225,000 |
20' |
50' |
27'
9" |
| ETU250-50 |
125,000 |
20' |
50' |
27'
9" |
| ETU180-60 |
180,000 |
18' |
60' |
32'
9" |
| ETU200-60 |
200,000 |
18' |
60' |
32'
9" |
| ETU225-60 |
225,000 |
20' |
60' |
32'
9" |
| ETU250-60 |
250,000 |
20' |
60' |
32'
9" |
| ETU180-70 |
180,000 |
18' |
70' |
37'
9" |
| ETU200-70 |
200,000 |
18' |
70' |
37'
9" |
| ETU225-70 |
225,000 |
20' |
70' |
37'
9" |
| ETU250-70 |
250,000 |
20' |
70' |
37'
9" |
| ETU180-80 |
180,000 |
18' |
80' |
42'
9" |
| ETU200-80 |
200,000 |
18' |
80' |
42'
9" |
| ETU225-80 |
225,000 |
20' |
80' |
42'
9" |
| ETU250-80 |
250,000 |
20' |
80' |
42'
9" |
|
|
|
|
|
|
Gas
and Electrical Supply Requirements
|
|
ETS/U
40--175
|
|
GAS
TYPE
|
BURNER
PRESSURE
|
SUPPLY
PRESSURE
|
VOLTAGE
|
AMPS
|
IGNITION
TYPE
|
|
Minimum
|
Maximum
|
|
NATURAL
|
3.5"
W.C. |
5"
W.C. |
14"
W.C. |
120
VAC
60
HZ |
2.6
|
DIRECT
SPARK |
|
PROPANE
|
10"
W.C. |
11"
W.C. |
14"
W.C. |
|
NATURAL
|
3.5"
W.C. |
5"
W.C. |
14"
W.C. |
120
VAC
60
HZ |
2.6
|
DIRECT
SPARK |
|
PROPANE
|
10"
W.C. |
11"
W.C. |
14"
W.C. |
|
ETS/U
180--250
|
|
NATURAL
|
3.5"
W.C. |
7"
W.C. |
14"
W.C. |
120
VAC
60
HZ |
2.6
|
DIRECT
SPARK |
|
PROPANE
|
10"
W.C. |
12"
W.C. |
14"
W.C. |
NOTE:
For all installations higher than 2000 ft. above sea level
please consult the factory regarding
recommended derating of heaters.
MINIMUM
CLEARANCE TO COMBUSTIBLES
| MODEL
|
SIDE
|
CEILING* |
BELOW
|
ENDS
|
Mounted
at 45º Angle |
| FRONT
|
REAR
|
|
ETS/U40, ETS/U50
|
27"
|
6"
|
40"
|
30"
|
48"
|
12"
|
|
ETS/U60, ETS/U75
|
27"
|
6"
|
60"
|
30"
|
48"
|
12"
|
|
ETS/U80, ETS/U90
|
52"
|
6"
|
84"
|
30"
|
52"
|
12"
|
|
ETS/U100
|
66"
|
6"
|
88"
|
40"
|
66"
|
20"
|
|
ETS/U110,
ETS/U120, ETS/U125, ETS/U130
|
66"
|
6"
|
101"
|
40"
|
66"
|
20"
|
|
ETS/U140,
ETS/U150, ETS/U160, ETS/U175
|
84"
|
6"
|
106"
|
48"
|
84"
|
24"
|
|
ETS/U180,
ETS/U200, ETS/U225, ETS/U250
|
84"
|
18"
|
132"
** |
48"
|
84"
|
24"
|
NOTE: The
clearances specified above must be maintained to combustibles
and other materials that may be damaged by temperatures 90ºF
above ambient temperature. Clearances to combustibles are posted
on the reflector near the control end of the heater. In locations
used for storage of combustible materials where they may be
stacked below the heater, NFPA 54 requires that the installer
must post signs that will "specify the maximum permissible
stacking height to maintain the required clearances from the
heater to combustibles".
*
When used indirect vented, the clearance to the ceiling from
the top of the exhaust hood must be 12" for ETS/U40--ETS/U75,
18" for ETS/U80--ETS/U175, and 24" for ETS/U180--ETS/U250.
If optional corner or U-bend reflectors are not used, clearance
must be 18" (24" for ETS/U180--250).
**
72" clearance 20 downstream from the Control
Box
NOTE: Consult
the factory if reduced clearances are required. Also,
please note that this heater is NOT for
residential use.
|
|
|
To request
a quote or if you need additional information, please call Space-Ray
toll free at 800-438-4936 or send
us an email.
Besides
this Commercial / Industrial Infrared gas heating product line, other
Space-Ray divisions include: Poultry,
Construction & Garage
| home | about
us | products: industrial / poultry / construction / garage | news2use | contact
info. | email us | site
map |
©
2006 Copyright — Space-Ray, Division of Gas Fired Products, Inc.
— Charlotte, North Carolina USA
International Manufacturer of Infrared Radiant Gas Heaters
|
|