Corporate Home Page 1-Commercial/Industrial 2-Poultry-Animal 3-Construction/Temporary 4-Garage/Residential
Radiant Heat Features Radiant Heat Benefits  TUBE HEATERS - Tube Heater Overview - CB Series - LTU Series - LTS Series - ETS/U Series - PTS/U Series - RSTP Series  CERAMIC HEATERS - Ceramic Heater Overview - DK Series - RSCA Series
 ENGINEERING & DESIGN SERVICES - Compuheat Heat Loss Analysis - Short Form Specifications - Infrared Heating Engineering Manual  TECHNICAL SUPPORT - Sequence of Operations - Installation & Operating Instructions - Submittals - Troubleshooting Guide
Typical Applications Case Studies
Questions about Products Questions about Space-Ray All Other Questions
What's New! Space-Ray E-Newsletters E-Newsletters Sign Up
Overview History Parent Company Info.
Request Quote Email Us General Info. Maps Directions
Welcome to Space-Ray - Infrared Gas Heaters

Infrared Radiant Heating for Commercial / Industrial Applications


commercial / industrial
> products > tube heater - ets / etu series

These series, with more than 80 different configurations and in capacities from 40,000 to 250,000 Btu/hr, offer optimum flexibility in custom designing an infrared heating system.

The ETS series is available in multiple configurations (straight, L, Z, and expanded U-shape) with lengths from 15' to 80' long. For added versatility, 90° elbows, corner reflectors, and side reflectors are available for close area mounting near walls, doors, and corners.

The ETU series is available in s
even different configurations and provides more uniform radiant heat energy distribution. The ETU series is ideal for high heat loss areas and spot heating.

ETS / ETU Series Infrared Tube Heater

click pic for enlarged view

 

ETS / ETU Series
Product Brochures:


ETS / ETU Infrared Heater
(PDF)

Tube Heater Accessories (PDF)

Installation & Operating
Instructions:

I&O ETS / ETU 40-250 (PDF)

ETS / ETU Submittal Data (PDF)

 


Other Major Types of
Space-Ray Tube Heaters:

 

 

 

< back to top >


Specifications

Features
  • 19 different Btu sizes and more than 100 different configurations to custom design your infrared heating system
  • CSA design certified
  • Vented or indirect vented operation
  • Sidewall or through-the-roof venting
  • Natural and Propane gas models

Pull Through System

  • Products of combustion are pulled through the combustion chamber for increased radiant efficiency and greater safety
  • No draft hoods, totally enclosed combustion chamber
  • Heavy duty draft inducer with permanently lubricated, totally enclosed, fan cooled, and heavy duty ball bearing motor for maintenance-free operation
  • Draft inducer can be rotated 45 or 90 degrees for sidewall venting
Burner System
  • Heavy duty cast iron burner 10 year limited warranty on burner Inside or outside air for combustion Up to 50 ft. outside combustion air duct capability
  • Standard 6" combustion air duct opening Reliable direct spark ignition system and 100% Gas Shut-Off Safety Control
  • 30 second pre-purge prior to ignition
  • State-of-the-art step opening redundant combination gas valve for quiet ignition and added safety
  • Diaphragm air switch for proof of venting before gas flow and ignition
  • Diagnostic Monitoring Light system
  • Burner inspection sight glass
  • 36" Stainless Steel flexible gas connector included with control box

Radiant Emitter Tube System

  • 4" O.D. heavy duty calorized aluminized steel combustion chamber (10 feet) and heavy duty hot-rolled steel emitter tubes
  • Optional calorized aluminized steel radiant emitter tubes
  • 3 year limited warranty on the emitter tubes
  • Suitable for horizontal or angle mounting up to 45 degrees
  • Optional 90° elbows
  • Up to 75 feet sidewall vent capability
  • Optional 5' or 10' body extension packages

Reflector System

  • Highly efficient aluminum reflectors with reflectivity rating of 97.5%
  • Optional end, corner, side and U-bend reflectors
  • Optional decorative grille
  • Individual reflectors can be rotated up to 45° to direct heat where needed
  • Easy-to-use mounting brackets
 

Dimensions

MODEL
INPUT BTU/HR
MINIMUM MOUNTING HEIGHT
TOTAL TUBE LENGTH
OVERALL DIMENSION "L"
SHIPPING WEIGHT Lbs.**
ETS40-15
40,000
10'
15'
17' 9"
96
ETS50-15
50,000
11'
15'
17' 9"
96
ETS40-20
40,000
10'
20'
22' 9"
126
ETS50-20
50,000
11'
20'
22' 9"
126
ETS60-20
60,000
12'
20'
22' 9"
126
ETS75-20
75,000
13'
20'
22' 9"
126
ETS50-30
50,000
11'
30'
32' 9"
162
ETS60-30
60,000
12'
30'
32' 9"
165
ETS75-30
75,000
13'
30'
32' 9"
162
ETS80-30
80,000
13'
30'
32' 9"
162
ETS90-30
90,000
13'
30'
32' 9"
162
ETS100-30
100,000
14'
30'
32' 9"
162
ETS110-30
110,000
14'
30'
32' 9"
162
ETS120-30
120,000
14'
30'
32' 9"
162
ETS125-30
125,000
14'
30'
32' 9"
162
ETS130-30
130,000
15'
30'
32' 9"
162
ETS80-40
80,000
13'
40'
42' 9"
198
ETS90-40
90,000
13'
40'
42' 9"
198
ETS100-40
100,000
14'
40'
42' 9"
198
ETS110-40
110,000
14'
40'
42' 9"
198
ETS120-40
120,000
14'
40'
42' 9"
198
ETS125-40
125,000
14'
40'
42' 9"
198
ETS130-40
130,000
15'
40'
42' 9"
198
ETS140-40
140,000
15'
40'
42' 9"
198
ETS150-40
150,000
15'
40'
42' 9"
198
ETS160-40
160,000
16'
40'
42' 9"
198
ETS175-40
175,000
16'
40'
42' 9"
198
ETS125-50
125,000
14'
50'
52' 9"
234
ETS130-50
130,000
15'
50'
52' 9"
234
ETS140-50
140,000
15'
50'
52' 9"
234
ETS150-50
150,000
15'
50'
52' 9"
234
ETS160-50
160,000
16'
50'
52' 9"
234
ETS175-50
175,000
16'
50'
52' 9"
234
ETS180-50
180,000
18'
50'
52' 9"
234
ETS200-50
200,000
18'
50'
52' 9"
234
ETS225-50
225,000
20'
50'
52' 9"
234
ETS250-50*
250,000
20'
50'
52' 9"
234
ETS180-60
180,000
18'
60'
62' 9"
288
ETS200-60
200,000
18'
60'
62' 9"
288
ETS225-60
225,000
20'
60'
62' 9"
288
ETS250-60
250,000
20'
60'
62' 9"
288
ETS180-70
180,000
18'
70'
72' 9"
324
ETS200-70
200,000
18'
70'
72' 9"
324
ETS225-70
225,000
20'
70'
72' 9"
324
ETS250-70
250,000
20'
70'
72' 9"
324
ETS180-80
180,000
18'
80'
82' 9"
360
ETS200-80
200,000
18'
80'
82' 9"
360
ETS225-80
225,000
20'
80'
82' 9"
360
ETS250-80
250,000
20'
80'
82' 9"
360
* Unvented use
** Hanging weight is 80% of shipping weight

 

 

MODEL
INPUT
MINIMUM MOUNTING HEIGHT
TOTAL TUBE LENGTH
OVERALL DIMENSION "L"
SHIPPING WEIGHT Lbs.**
BTU/HR
ETU40-20
40,000
10'
20'
12' 9"
146
ETU50-20
50,000
11'
20'
12' 9"
146
ETU60-20
60,000
12'
20'
12' 9"
146
ETU75-20
75,000
13'
20'
12' 9"
146
ETU50-30
50,000
11'
30'
17' 9"
182
ETU60-30
60,000
12'
30'
17' 9"
182
ETU75-30
75,000
13'
30'
17' 9"
182
ETU80-30
80,000
13'
30'
17' 9"
182
ETU90-30
90,000
13'
30'
17' 9"
182
ETU100-30
100,000
14'
30'
17' 9"
182
ETU110-30
110,000
14'
30'
17' 9"
182
ETU120-30
120,000
14'
30'
17' 9"
182
ETU125-30
125,000
14'
30'
17' 9"
182
ETU130-30
130,000
15'
30'
17' 9"
182
ETU80-40
80,000
13'
40'
22' 9"
218
ETU90-40
90,000
13'
40'
22' 9"
218
ETU100-40
100,000
14'
40'
22' 9"
218
ETU110-40
110,000
14'
40'
22' 9"
218
ETU120-40
120,000
14'
40'
22' 9"
218
ETU125-40
125,000
14'
40'
22' 9"
218
ETU130-40
130,000
15'
40'
22' 9"
218
ETU140-40
140,000
15'
40'
22' 9"
218
ETU150-40
150,000
15'
40'
22' 9"
218
ETU160-40
160,000
16'
40'
22' 9"
218
ETU175-40
175,000
16'
40'
22' 9"
218
ETU125-50
125,000
14'
50'
27' 9"
254
ETU130-50
130,000
15'
50'
27' 9"
254
ETU140-50
140,000
15'
50'
27' 9"
254
ETU150-50
150,000
15'
50'
27' 9"
254
ETU160-50
160,000
16'
50'
27' 9"
254
ETU175-50
175,000
16'
50'
27' 9"
254
ETU180-50
180,000
18'
50'
27' 9"
254
ETU200-50
200,000
18'
50'
27' 9"
254
ETU225-50
225,000
20'
50'
27' 9"
254
ETU250-50
125,000
20'
50'
27' 9"
254
ETU180-60
180,000
18'
60'
32' 9"
308
ETU200-60
200,000
18'
60'
32' 9"
308
ETU225-60
225,000
20'
60'
32' 9"
308
ETU250-60
250,000
20'
60'
32' 9"
308
ETU180-70
180,000
18'
70'
37' 9"
344
ETU200-70
200,000
18'
70'
37' 9"
344
ETU225-70
225,000
20'
70'
37' 9"
344
ETU250-70
250,000
20'
70'
37' 9"
344
ETU180-80
180,000
18'
80'
42' 9"
380
ETU200-80
200,000
18'
80'
42' 9"
380
ETU225-80
225,000
20'
80'
42' 9"
380
ETU250-80
250,000
20'
80'
42' 9"
380
** Hanging weight is 80% of shipping weight

Supply Requirements

Gas and Electrical Supply Requirements

ETS/U 40--175

GAS TYPE

BURNER PRESSURE

SUPPLY PRESSURE

VOLTAGE

AMPS

IGNITION TYPE

Minimum

Maximum

NATURAL

3.5" W.C.

5" W.C.

14" W.C.

120 VAC

60 HZ

2.6

DIRECT SPARK

PROPANE

10" W.C.

11" W.C.

14" W.C.

NATURAL

3.5" W.C.

5" W.C.

14" W.C.

120 VAC

60 HZ

2.6

DIRECT SPARK

PROPANE

10" W.C.

11" W.C.

14" W.C.

ETS/U 150--250

NATURAL

3.5" W.C.

7" W.C.

14" W.C.

120 VAC

60 HZ

2.6

DIRECT SPARK

PROPANE

10" W.C.

12" W.C.

14" W.C.


NOTE: For all installations higher than 2000 ft. above sea level please consult the factory regarding
recommended derating of heaters.
Clearance Information
MINIMUM CLEARANCE TO COMBUSTIBLES

MODEL

SIDE

CEILING*

BELOW

ENDS

Mounted at 45º Angle

FRONT

REAR

ETS/U40, ETS/U50

27"

6"

40"

30"

48"

12"

ETS/U60, ETS/U75

27"

6"

60"

30"

48"

12"

ETS/U80, ETS/U90

52"

6"

84"

30"

52"

12"

ETS/U100

66"

6"

88"

40"

66"

20"

ETS/U110, ETS/U120, ETS/U125, ETS/U130

66"

6"

101"

40"

66"

20"

ETS/U140, ETS/U150, ETS/U160, ETS/U175

84"

6"

106"

48"

84"

24"

ETS/U180, ETS/U200, ETS/U225, ETS/U250

84"

18"

132" **

48"

84"

24"

NOTE: The clearances specified above must be maintained to combustibles and other materials that may be damaged by temperatures 90ºF above ambient temperature. Clearances to combustibles are posted on the reflector near the control end of the heater. In locations used for storage of combustible materials where they may be stacked below the heater, NFPA 54 requires that the installer must post signs that will "specify the maximum permissible stacking height to maintain the required clearances from the heater to combustibles".

* When used indirect vented, the clearance to the ceiling from the top of the exhaust hood must be 12" for ETS/U40--ETS/U75, 18" for ETS/U80--ETS/U175, and 24" for ETS/U180--ETS/U250. If optional corner or U-bend reflectors are not used, clearance must be 18" (24" for ETS/U180--250).

** 72" clearance 20’ downstream from the Control Box

NOTE: Consult the factory if reduced clearances are required. Also, please note that this heater is NOT for residential use.


 


email us

To request a quote or if you need additional information, please call Space-Ray toll free at 800-438-4936 or send us an email.

Besides this Commercial / Industrial Infrared gas heating product line, other Space-Ray divisions include: poultry, Construction & Garage

| home | about us | products: industrial / poultry / construction / garage | news2use | contact info. | email us | site map |

© 2006 Copyright — Space-Ray, Division of Gas Fired Products, Inc. — Charlotte, North Carolina   USA
International Manufacturer of Infrared Radiant Gas Heaters


return HOME email us