Corporate Home Page 1-Commercial/Industrial 2-Poultry-Animal 3-Construction/Temporary 4-Garage/Residential
Radiant Heat Features Radiant Heat Benefits  TUBE HEATERS - Tube Heater Overview - CB Series - LTU Series - LTS Series - ETS/U Series - PTS/U Series - RSTP Series  CERAMIC HEATERS - Ceramic Heater Overview - DK Series - RSCA Series
 ENGINEERING & DESIGN SERVICES - Compuheat Heat Loss Analysis - Short Form Specifications - Infrared Heating Engineering Manual  TECHNICAL SUPPORT - Sequence of Operations - Installation & Operating Instructions - Submittals - Troubleshooting Guide
Typical Applications Case Studies
Questions about Products Questions about Space-Ray All Other Questions
What's New! Space-Ray E-Newsletters E-Newsletters Sign Up
Overview History Parent Company Info.
Request Quote Email Us General Info. Maps Directions
Welcome to Space-Ray - Infrared Gas Heaters

Infrared Radiant Heating for Commercial / Industrial Applications


commercial / industrial
> products > tube heater - pts / ptu series

These series, with more than 80 different configurations and in capacities from 40,000 to 200000 Btu/hr, offer optimum flexibility in custom designing an infrared heating system.

The PTS series is available in multiple configurations (straight, L, Z, and expanded U-shape) with lengths from 10' to 70' long. For added versatility, 90° elbows, corner reflectors, and side reflectors are available for close area mounting near walls, doors, and corners.

The PTU series is available in seven different configurations and provides more uniform radiant heat energy distribution. The PTU series is ideal for high heat loss areas and spot heating.

PTS / PTU Series Infrared Tube Heater

click pic for enlarged view

 

PTS / PTU Series
Product Brochures:


PTS / PTU Infrared Heater
(PDF)

Tube Heater Accessories (PDF)

Installation & Operating
Instructions:

I&O PTS / PTU Single Stage (PDF)

I&O PTS / PTU Two Stage
(PDF)

 

PTS / PTU Submittal Data (PDF)

 


Other Major Types of
Space-Ray Tube Heaters:

 

 

 

< back to top >


Specifications

Features
  • 8 different Btu/hr sizes and more than 100 different Configurations to custom design your infrared heating system
  • Single Stage or Two Stage Modulation Input Controls
  • CSA design certified
  • Vented or indirect vented operation
  • Sidewall or through-the-roof venting
  • Natural and propane gas models
  • Single stage or two stage modulating input

Push Through System (positive presure)

  • Products of combustion are pushed through the combustion chamber
  • Tube Integrity Safety System (TISS)
  • No draft hoods, totally enclosed combustion chamber
  • Blower motor totally enclosed in the burner box, ideal for applications where minimal noise (less than 60dB) is desired
  • Heavy duty permanently lubricated ball bearing blower motor for maintenance-free operation
Burner System
  • Heavy duty cast iron burner
  • 10- year limited warranty on burner
  • Inside or outside air for combustion
  • Up to 40 ft. outside combustion air duct capability
  • Standard 4" combustion air collar
  • Reliable direct spark ignition system and 100% gas shut-off safety control
  • Pre-purge and post-purge function
  • State-of-the-art step opening redundant combination gas valve for quiet ignition and added safety
  • Diaphragm air switch for proof of venting before gas flow and ignition
  • Diagnostic monitoring light system
  • Burner inspection sight glass
  • Line voltage or 24V thermostat connection
  • 36" stainless steel flexible gas connector included with burner box
Radiant Emitter Tube System
  • 4" O. D. heavy-duty calorized aluminized steel or alumi-therm steel combustion chamber (10 feet) and heavy duty hot-rolled steel radiant emitter tubes
  • Optional calorized aluminized steel (ALC) radiant emitter tubes
  • 3-year limited warranty on the emitter tubes
  • Suitable for horizontal or angle mounting up to 45°
  • Optional 90° elbows
  • Up to 40 feet sidewall vent capacity
  • Optional 5' or 10' body extension packages

ALC Option: All calorized aluminized steel (ALC) radiant emitter tubes for ALC option the model number would be PTS100-40-ALC-N5. Note: for Carwashes, Dairy Barns, Greenhouses, Swimming Pools, Waste Water Treatment Plants, and other high humidity/corrosive environments, ALC option with all calorized aluminized tubes is recommended

Reflector System
  • Optional end, corner, side and U-bend reflectors
  • Optional decorative grille
  • Individual reflectors can be rotated up to 45° to direct heat where needed
  • Easy-to-use mounting brackets
 

Model Selection

 

Single Stage
Btu/Hr Input
Two Stage
Model
Btu/Hr High Input
Btu/Hr Low Input
PTS/U 40
40,000 40,000 25,000
PTS/U 50
50,000 50,000 30,000
PTS/U 75
75,000 75,000 50,000
PTS/U 100
100,000 100,000 65,000
PTS/U 125
125,000 125,000 80,000
PTS/U 150
150,000 150,000 100,000
PTS/U 175
175,000 175,000 110,000
PTS/U 200
200,000 200,000 125,000

    * Indicate model number based on Btu/hr input (eg., 100,000 Btu/hr), emitter length, (e.g., 40 feet) and gas type/control suffix (e.g., natural gas single stage input). The unit selection for straight tube would be PTS100-40-N5 and for a u-tube would be PTU-40-N5.

Control Suffix
Type of Gas
Control Option Description
N5/ L5
Natural / Propane
Single Stage Gas Valve- Single Stage Input
N7 / L7
Natural / Propane
Two Stage Gas Valve- modulating Input – High/Low Fire

Dimensions
Infrared Heater Dimensions
MODEL
INPUT BTU/HR
MINIMUM MOUNTING HEIGHT
TOTAL TUBE LENGTH
OVERALL DIMENSION "L"
SHIPPING WEIGHT Lbs.**
PTS40-10
40,000
10'
10'
11' 2"
80
PTS40-20
40,000
10'
20'
21' 2"
130
PTS50-20
50,000
11'
20'
21' 2"
130
PTS75-20
75,000
13'
20'
21' 2"
130
PTS50-30
50,000
11'
30'
31' 2"
166
PTS75-30
75,000
13'
30'
31' 2"
166
PTS100-30
100,000
14'
30'
31' 2"
166
PTS125-30
125,000
14'
30'
31' 2"
166
PTS100-40
100,000
14'
40'
41' 2"
202
PTS125-40
125,000
14'
40'
41' 2"
202
PTS150-40
150,000
15'
40'
41' 2"
202
PTS175-40
175,000
16'
40'
41' 2"
202
PTS125-50
125,000
14'
50'
51' 2"
238
PTS150-50
150,000
15'
50'
51' 2"
238
PTS175-50
175,000
16'
50'
51' 2"
238
PTS200-50
200,000
18'
50'
51' 2"
238
PTS150-60
150,000
18'
60'
61' 2"
292
PTS175-60
175,000
20'
60'
61' 2"
292
PTS200-60
200,000
18'
60'
61' 2"
292
PTS175-70
175,000
18'
70'
71' 2"
328
PTS200-70
200,000
18'
70'
71' 2"
328
** Hanging weight is 80% of shipping weight

 

Infrared Heater Dimensions
MODEL
INPUT
MINIMUM MOUNTING HEIGHT
TOTAL TUBE LENGTH
OVERALL DIMENSION "L"
SHIPPING WEIGHT Lbs.**
BTU/HR
PTU40-20
40,000
10'
20'
12' 5"
130
PTU50-20
50,000
11'
20'
12' 5"
130
PTU75-20
75,000
13'
20'
12' 5"
130
PTU50-30
50,000
11'
30'
17' 5"
166
PTU75-30
75,000
13'
30'
17' 5"
166
PTU100-30
100,000
14'
30'
17' 5"
166
PTU125-30
125,000
14'
30'
17' 5"
166
PTU100-40
100,000
14'
40'
22' 5"
202
PTU125-40
125,000
14'
40'
22' 5"
202
PTU150-40
150,000
15'
40'
22' 5"
202
PTU175-40
175,000
16'
40'
22' 5"
202
PTU125-50
125,000
14'
50'
27' 5"
238
PTU150-50
150,000
15'
50'
27' 5"
238
PTU175-50
175,000
16'
50'
27' 5"
238
PTU200-50
200,000
18'
50'
27' 5"
238
PTU150-60
150,000
18'
60'
32' 5"
292
PTU175-60
175,000
18'
60'
32' 5"
292
PTU200-60
200,000
18'
60'
32' 5"
292
PTU175-70
175,000
18'
70'
37' 5"
328
PTU200-70
200,000
20'
70'
37' 5"
328
** Hanging weight is 80% of shipping weight

Supply Requirements

Gas and Electrical Supply Requirements
PTS/U 40--200
GAS TYPE
BURNER PRESSURE
SUPPLY PRESSURE
VOLTAGE
AMPS
IGNITION TYPE
MINIMUM
MAXIMUM
NATURAL
3.5" W.C.
5" W.C.
14" W.C.
120 VAC
60 HZ
1.8
DIRECT SPARK
PROPANE
10" W.C.
11" W.C.
14" W.C.

NOTE: For all installations higher than 2000 ft. above sea level please consult the factory regarding recommended derating of heaters.
Clearance Information
 
MINIMUM CLEARANCE TO COMBUSTIBLES

 
MODEL
SIDE
CEILING*
BELOW
ENDS
Mounted at 45º Angle
FRONT
REAR
PTS/U40, PTS/U50
27"
6"
40"
30"
48"
12"
PTS/U75
27"
6"
60"
30"
48"
12"
PTS/U100
66"
6"
88"
40"
66"
20"
PTS/U125
66"
6"
101"
40"
66"
20"
PTS/U150, PTS/U175
84"
6"
106"
48"
84"
24"
PTS/U200
84"
18"
132" **
48"
84"
24"

NOTE: The clearances specified above must be maintained to combustibles and other materials that may be damaged by temperatures 90ºF above ambient temperature. Clearances to combustibles are posted on the reflector near the control end of the heater. In locations used for storage of combustible materials where they may be stacked below the heater, NFPA 54 requires that the installer must post signs that will "specify the maximum permissible stacking height to maintain the required clearances from the heater to combustibles".

* When used indirect vented, the clearance to the ceiling from the top of the exhaust hood must be 12" for PTS/U75--PTS/U50, 18" for PTS/U100--PTS/U200. If optional corner or U-bend reflectors are not used, clearance must be 18" (24" for PTS/U180--250).

** 72" clearance 20’ downstream from the Control Box

NOTE: Consult the factory if reduced clearances are required. Also, please note that this heater is NOT for residential use.

 


email us

To request a quote or if you need additional information, please call Space-Ray toll free at 800-438-4936 or send us an email.

Besides this Commercial / Industrial Infrared gas heating product line, other Space-Ray divisions include: poultry, Construction & Garage

| home | about us | products: industrial / poultry / construction / garage | news2use | contact info. | email us | site map |

© 2006 Copyright — Space-Ray, Division of Gas Fired Products, Inc. — Charlotte, North Carolina   USA
International Manufacturer of Infrared Radiant Gas Heaters


return HOME email us