Corporate Home Page 1-Commercial/Industrial 2-Poultry-Animal 3-Construction/Temporary 4-Garage/Residential
Radiant Heat Features Radiant Heat Benefits  TUBE HEATERS - Tube Heater Overview - CB Series - LTU Series - LTS Series - ETS/U Series - PTS/U Series - RSTP Series  CERAMIC HEATERS - Ceramic Heater Overview - DK Series - RSCA Series
 ENGINEERING & DESIGN SERVICES - Compuheat Heat Loss Analysis - Short Form Specifications - Infrared Heating Engineering Manual  TECHNICAL SUPPORT - Sequence of Operations - Installation & Operating Instructions - Submittals - Troubleshooting Guide
Typical Applications Case Studies
Questions about Products Questions about Space-Ray All Other Questions
What's New! Space-Ray E-Newsletters E-Newsletters Sign Up
Overview History Parent Company Info.
Request Quote Email Us General Info. Maps Directions
Welcome to Space-Ray - Infrared Gas Heaters

Infrared Radiant Heating for Commercial / Industrial Applications


commercial / industrial
> products > tube heater - pts / ptu series

These series, with more than 80 different configurations and in capacities from 40,000 to 200000 Btu/hr, offer optimum flexibility in custom designing an infrared heating system.

The PTS series is available in multiple configurations (straight, L, Z, and expanded U-shape) with lengths from 10' to 70' long. For added versatility, 90° elbows, corner reflectors, and side reflectors are available for close area mounting near walls, doors, and corners.

The PTU series is available in seven different configurations and provides more uniform radiant heat energy distribution. The PTU series is ideal for high heat loss areas and spot heating.

PTS / PTU Series Infrared Tube Heater

click pic for enlarged view

 

PTS / PTU Series
Product Brochures:


PTS / PTU Infrared Heater
(PDF)

Tube Heater Accessories (PDF)

Installation & Operating
Instructions:

I&O PTS / PTU Single Stage (PDF)

I&O PTS / PTU Two Stage
(PDF)

 

PTS / PTU Submittal Data (PDF)

 


Other Major Types of
Space-Ray Tube Heaters:

 

 

 

< back to top >


Specifications

Features
  • 8 different Btu/hr sizes and more than 100 different Configurations to custom design your infrared heating system
  • Single Stage or Two Stage Modulation Input Controls
  • CSA design certified
  • Vented or indirect vented operation
  • Sidewall or through-the-roof venting
  • Natural and propane gas models

Push Through System (positive presure)

  • Products of combustion are pushed through the combustion chamber
  • Tube Integrity Safety System (TISS)
  • No draft hoods, totally enclosed combustion chamber
  • Blower motor totally enclosed in the burner box, ideal for applications where minimal noise (less than 60dB) is desired
  • Heavy duty permanently lubricated ball bearing blower motor for maintenance-free operation
Burner System
  • Heavy duty cast iron burner
  • 10- year limited warranty on burner
  • Inside or outside air for combustion
  • Up to 40 ft. outside combustion air duct capability
  • Standard 4" combustion air collar
  • Reliable direct spark ignition system and 100% gas shut-off safety control
  • Pre-purge and post-purge function
  • State-of-the-art step opening redundant combination gas valve for quiet ignition and added safety
  • Diaphragm air switch for proof of venting before gas flow and ignition
  • Diagnostic monitoring light system
  • Burner inspection sight glass
  • Line voltage or 24V thermostat connection
Radiant Emitter Tube System
  • 4" O. D. heavy-duty calorized aluminized steel or alumi-therm steel combustion chamber (10 feet) and heavy duty hot-rolled steel radiant emitter tubes
  • Optional calorized aluminized steel (ALC) radiant emitter tubes
  • 3-year limited warranty on the emitter tubes
  • Suitable for horizontal or angle mounting up to 45°
  • Optional 90° elbows
  • Up to 40 feet sidewall vent capacity

ALC Option: All calorized aluminized steel (ALC) radiant emitter tubes for ALC option the model number would be PTS100-40-ALC-N5. Note: for Carwashes, Dairy Barns, Greenhouses, Swimming Pools, Waste Water Treatment Plants, and other high humidity/corrosive environments, ALC option with all calorized aluminized tubes is recommended

Reflector System
  • Optional end, corner, side and U-bend reflectors
  • Optional decorative grille
  • Individual reflectors can be rotated up to 45° to direct heat where needed
  • Easy-to-use mounting brackets
 

Model Selection

 

Single Stage
Btu/Hr Input
Two Stage
Model
Btu/Hr High Input
Btu/Hr Low Input
PTS/U 40
40,000 40,000 25,000
PTS/U 50
50,000 50,000 30,000
PTS/U 75
75,000 75,000 50,000
PTS/U 100
100,000 100,000 65,000
PTS/U 125
125,000 125,000 80,000
PTS/U 150
150,000 150,000 100,000
PTS/U 175
175,000 175,000 110,000
PTS/U 200
200,000 200,000 125,000

      Indicate model number based on Btu/hr input (eg., 100,000 Btu/hr), emitter length, (e.g., 40 feet) and gas type/control suffix (e.g., natural gas single stage input). The unit selection for straight tube would be PTS100-40-N5 and for a u-tube would be PTU-40-N5.

Control Suffix Type of Gas Control Option Description
N5/ L5 Natural / Propane Single Stage Gas Valve- Single Stage Input
N7 / L7 Natural / Propane Two Stage Gas Valve- Two Stage Input – High/Low Fire

Dimensions
Infrared Heater Dimensions

MODEL

INPUT BTU/HR

MINIMUM MOUNTING HEIGHT

TOTAL TUBE LENGTH

OVERALL DIMENSION "L"

PTS40-10
40,000
10'
15'
11' 2"
PTS40-20
40,000
10'
20'
21' 2"
PTS50-20
50,000
11'
20'
21' 2"
PTS75-20
75,000
13'
20'
21' 2"
PTS50-30
50,000
11'
30'
31' 2"
PTS75-30
75,000
13'
30'
31' 2"
PTS100-30
100,000
14'
30'
31' 2"
PTS125-30
125,000
14'
30'
31' 2"
PTS100-40
100,000
14'
40'
41' 2"
PTS125-40
125,000
14'
40'
41' 2"
PTS150-40
150,000
15'
40'
41' 2"
PTS175-40
175,000
16'
40'
41' 2"
PTS125-50
125,000
14'
50'
51' 2"
PTS150-50
150,000
15'
50'
51' 2"
PTS175-50
175,000
16'
50'
51' 2"
PTS200-50
200,000
18'
50'
51' 2"
PTS150-60
150,000
18'
60'
61' 2"
PTS175-60
175,000
20'
60'
61' 2"
PTS200-60
200,000
18'
60'
61' 2"
PTS175-70
175,000
18'
70'
71' 2"
PTS200-70
200,000
18'
70'
71' 2"

 

Infrared Heater Dimensions

MODEL

INPUT
BTU/HR

MINIMUM MOUNTING HEIGHT

TOTAL TUBE LENGTH

OVERALL DIMENSION "L"

PTU40-20
40,000
10'
20'
12' 5"
PTU50-20
50,000
11'
20'
12' 5"
PTU75-20
75,000
13'
20'
12' 5"
PTU50-30
50,000
11'
30'
17' 5"
PTU75-30
75,000
13'
30'
17' 5"
PTU100-30
100,000
14'
30'
17' 5"
PTU125-30
125,000
14'
30'
17' 5"
PTU100-40
100,000
14'
40'
22' 5"
PTU125-40
125,000
14'
40'
22' 5"
PTU150-40
150,000
15'
40'
22' 5"
PTU175-40
175,000
16'
40'
22' 5"
PTU125-50
125,000
14'
50'
27' 5"
PTU150-50
150,000
15'
50'
27' 5"
PTU175-50
175,000
16'
50'
27' 5"
PTU200-50
200,000
18'
50'
27' 5"
PTU150-60
150,000
18'
60'
32' 5"
PTU175-60
175,000
18'
60'
32' 5"
PTU200-60
200,000
18'
60'
32' 5"
PTU175-70
175,000
18'
70'
37' 5"
PTU200-70
200,000
20'
70'
37' 5"

Supply Requirements

Gas and Electrical Supply Requirements
PTS/U 40--200
GAS TYPE
BURNER PRESSURE
SUPPLY PRESSURE
VOLTAGE
AMPS
IGNITION TYPE
MINIMUM
MAXIMUM
NATURAL
3.5" W.C.
5" W.C.
14" W.C.
120 VAC
60 HZ
1.8
DIRECT SPARK
PROPANE
10" W.C.
11" W.C.
14" W.C.

NOTE: For all installations higher than 2000 ft. above sea level please consult the factory regarding recommended derating of heaters.
Clearance Information

 

MINIMUM CLEARANCE TO COMBUSTIBLES

 

MODEL
SIDE
CEILING*
BELOW
ENDS
Mounted at 45º Angle
FRONT
REAR
PTS/U40, PTS/U50
27"
6"
40"
30"
48"
12"
PTS/U75
27"
6"
60"
30"
48"
12"
PTS/U100
66"
6"
88"
40"
66"
20"
PTS/U125
66"
6"
101"
40"
66"
20"
PTS/U150, PTS/U175
84"
6"
106"
48"
84"
24"
PTS/U200
84"
18"
132" **
48"
84"
24"

NOTE: The clearances specified above must be maintained to combustibles and other materials that may be damaged by temperatures 90ºF above ambient temperature. Clearances to combustibles are posted on the reflector near the control end of the heater. In locations used for storage of combustible materials where they may be stacked below the heater, NFPA 54 requires that the installer must post signs that will "specify the maximum permissible stacking height to maintain the required clearances from the heater to combustibles".

* When used indirect vented, the clearance to the ceiling from the top of the exhaust hood must be 12" for PTS/U75--PTS/U50, 18" for PTS/U100--PTS/U200. If optional corner or U-bend reflectors are not used, clearance must be 18" (24" for PTS/U180--250).

** 72" clearance 20’ downstream from the Control Box

NOTE: Consult the factory if reduced clearances are required. Also, please note that this heater is NOT for residential use.

 


email us

To request a quote or if you need additional information, please call Space-Ray toll free at 800-438-4936 or send us an email.

Besides this Commercial / Industrial Infrared gas heating product line, other Space-Ray divisions include: Poultry, Construction & Garage

| home | about us | products: industrial / poultry / construction / garage | news2use | contact info. | email us | site map |

© 2006 Copyright — Space-Ray, Division of Gas Fired Products, Inc. — Charlotte, North Carolina   USA
International Manufacturer of Infrared Radiant Gas Heaters


return HOME email us