* Indicate model number based on Btu/hr input (e.g. 50,000Btu/hr), emitter length (e.g. 15 ft.) . Control suffix (e.g. Natural Gas single stage input ) . The unit selection would be CB50-15-N5.
Control Suffix
Type of Gas
Control Option Description
N5/ L5
Natural / Propane
Single Stage Gas Valve- Single Stage Input
N7 / L7
Natural / Propane
Two Stage Gas Valve- Modulating Input – High/Low Fire
NOTE: The
clearances specified above must be maintained to combustibles and
other materials that may be damaged by temperatures 90ºF above
ambient temperature. Clearances to combustibles are posted on the
reflector near the control end of the heater. In locations used for
storage of combustible materials where they may be stacked below
the heater, NFPA 54 requires that the installer must post signs that
will "specify the maximum permissible stacking height to maintain
the required clearances from the heater to combustibles".
Accessories
Deflector
Kit
Lower Mounting Kit The Lower
Mounting Kit (Part #43515000) is required when the
CB series of infrared tube heaters is installed at mounting
heights between 6 ft. and 8 ft. above a finished floor. The
Lower Mounting Kit consists of both the Emitter Guard Kit
and the Draft Inducer Guard Kit as described below.
1. Emitter Guard Kit
The Emitter Guard Kit (Part #43485000) includes
an aluminum decorative grille with side emitter guard holder
panels. This item and the Draft Inducer Guard Kit make
up the Lower Mounting Kit, which must be used in installations
with mounting heights between 6 ft. and 8 ft. This
item could be used separately in installations above 8 ft.,
however, for decorative purposes if desired.
2. Draft
Inducer Guard Kit The Draft Inducer Guard Kit (Part
#43486000) is an aluminum shield mounted around the draft
inducer (brackets and screws included).
This item and the Emitter
Guard Kit make up the Lower Mounting Kit, which must be
used in installations with mounting heights between 6 ft.
and 8 ft.